型號
|
PSU 6-200
|
PSU 12.5-120
|
PSU 20-76
|
PSU 40-38
|
PSU60-25
|
|
|
額定輸出
|
|
|
|
|
|
|
|
電壓
|
0~6V
|
0~12.5V
|
0~20V
|
0~40V
|
0~60V
|
|
|
電流
|
0~200A
|
0~120A
|
0~76A
|
0~38A
|
0~25A
|
|
|
功率
|
1200W
|
1500W
|
1520W
|
1520W
|
1500W
|
|
|
輸出紋波和噪聲
|
|
|
|
|
|
|
|
CV p-p (0~20MHz)
|
60mV
|
60mV
|
60mV
|
60mV
|
60mV
|
|
|
CV rms (5Hz~1MHz)
|
8mV
|
8mV
|
8mV
|
8mV
|
8mV
|
|
|
CC rms (5Hz~1MHz)
|
400mA
|
240mA
|
152mA
|
95mA
|
75mA
|
|
|
負載調節率(滿載10%~90%)
|
|
|
|
|
|
|
|
電壓(0.01%F.S.+2mV)
|
2.6mV
|
3.25mV
|
4mV
|
6mV
|
8mV
|
|
|
電流(0.02%F.S.+2mA)
|
45mA
|
29mA
|
20.2mA
|
12.6mA
|
10mA
|
|
|
電壓調節率(85~132 VAC輸入或170~265 VAC)
|
|
|
|
|
|
|
|
電壓(0.01%F.S.+2mV)
|
2.6mV
|
3.25mV
|
4mV
|
6mV
|
8mV
|
|
|
電流(0.02%F.S.+2mA)
|
22mA
|
14mA
|
9.6mA
|
5.8mA
|
4.5mA
|
|
|
編程精度
|
|
|
|
|
|
|
|
電壓0.05%+偏移(mV)
|
3mV
|
6.25mV
|
10mV
|
20mV
|
30mV
|
|
|
電流0.2%+偏移(mA)
|
200mA
|
120mA
|
76mA
|
38mA
|
25mA
|
|
|
測量精度
|
|
|
|
|
|
|
|
電壓0.1%+偏移(mV)
|
6mV
|
12.5mV
|
20mV
|
40mV
|
60mV
|
|
|
電流0.1%+偏移(mA)
|
400mA
|
240mA
|
152mA
|
76mA
|
50mA
|
|
|
負載瞬間恢復時間
|
|
|
|
|
|
|
|
時間
|
1.5ms
|
1.5ms
|
1ms
|
1ms
|
1ms
|
|
|
輸出響應時間(使用0~10V步進的
|
|
|
|
|
|
|
|
模擬編程源和電阻負載測量)
|
|
|
|
|
|
|
|
上升時間(空載&滿載)
|
80ms
|
80ms
|
80ms
|
80ms
|
80ms
|
|
|
下降時間(空載)
|
500ms
|
700ms
|
800ms
|
1000ms
|
1100ms
|
|
|
下降時間(滿載)
|
10ms
|
50ms
|
50ms
|
80ms
|
80ms
|
|
|
編程/測量分辨率
|
|
|
|
|
|
|
|
電壓
|
0.2mV
|
0.4mV
|
0.7mV
|
1.3mV
|
2mV
|
|
|
電流
|
6mA
|
4mA
|
2.5mA
|
1.2mA
|
0.8mA
|
|
|
溫度系數(熱機30分鐘)
|
|
|
|
|
|
|
|
電壓
|
100PPM/℃
|
|
|
|
|
|
|
電流
|
100PPM/℃
|
|
|
|
|
|
|
串并聯操作
|
|
|
|
|
|
|
|
并聯操作
|
含主機*多4臺
|
|
|
|
|
|
|
串聯操作
|
含主機*多2臺
|
|
|
|
|
|
|
環境條件
|
|
|
|
|
|
|
|
環境
|
室內,安裝等級II(AC輸入),污染等級2
|
|
|
|
|
操作溫度范圍
|
0℃~50℃
|
|
|
|
|
|
|
存儲溫度范圍
|
-25℃~70℃
|
|
|
|
|
|
|
操作濕度范圍
|
20%~85%RH
|
|
|
|
|
|
|
存儲濕度范圍
|
*高90%或小于相對濕度(無凝結)
|
|
|
|
|
AC輸入
|
|
|
|
|
|
|
|
正常輸入
|
100 VAC~240 VAC,50Hz~60Hz,單相位
|
|
|
|
|
輸入范圍
|
85 VAC~265 VAC
|
|
|
|
|
|
|
功率因數(100Vac/200Vac)
|
0.99/0.98
|
|
|
|
|
|
|
*大輸入電流(100Vac/200Vac)
|
21A/11A
|
|
|
|
|
|
|
浪涌電流
|
≤50A
|
|
|
|
|
|
|
效率(100Vac/200Vac)
|
77%/79%
|
82%/85%
|
83%/86%
|
84%/88%
|
84%/88%
|
|
|
模擬控制(非獨立)
|
有
|
|
|
|
|
|
|
PC遠程接口(標配)
|
USB(Device/Host)/RS-232, RS-485/LAN
|
|
|
|
|
PC遠程接口(選配)
|
GPIB/模擬控制接口(獨立電壓控制)/模擬控制接口(獨立電流控制);
|
|
|
注:三選一
|
|
|
|
|
|
|
|
溫控風扇
|
內部風扇冷卻
|
|
|
|
|
|
|
尺寸&重量
|
422.8(W)×43.6(H)×432.8(D);約8.7kg
|
|
|
|
|
|
|
|
|
|
|
|
|
型號
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
額定電壓 (*1)
|
|
V
|
100
|
150
|
300
|
400
|
600
|
額定電流 (*2)
|
|
A
|
15
|
10
|
5
|
3.8
|
2.6
|
額定功率
|
|
W
|
1500
|
1500
|
1500
|
1520
|
1560
|
|
|
|
|
|
|
|
|
定電壓模式
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
電源調節率 (*3)
|
|
mV
|
12
|
17
|
32
|
42
|
62
|
負載調節率 (*4)
|
|
mV
|
12
|
17
|
32
|
42
|
62
|
輸出漣波及雜訊(*5)
|
p-p (*6)
|
mV
|
80
|
100
|
150
|
200
|
300
|
|
r.m.s. (*7)
|
mV
|
8
|
10
|
25
|
40
|
60
|
溫度系數
|
|
ppm/℃
|
100ppm/℃ after a 30 minute warm-up
|
偵測補償電壓 (single wire)
|
|
V
|
5
|
5
|
5
|
5
|
5
|
上升時間 (*8)
|
Rated load
|
ms
|
150
|
150
|
150
|
200
|
250
|
|
No load
|
ms
|
150
|
150
|
150
|
200
|
250
|
下降時間(*9)
|
Rated load
|
ms
|
150
|
150
|
150
|
200
|
250
|
|
No load
|
ms
|
1500
|
2000
|
2500
|
3000
|
4000
|
負載變動回復時間 (*10)
|
|
ms
|
1
|
2
|
2
|
2
|
2
|
|
|
|
|
|
|
|
|
定電流模式
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
電源調節率(*3)
|
|
mA
|
3.5
|
3
|
2.5
|
2.38
|
2.26
|
負載調節率(*11)
|
|
mA
|
8
|
7
|
6
|
5.76
|
5.52
|
輸出漣波及雜訊(*12)
|
r.m.s.
|
mA
|
45
|
35
|
25
|
17
|
12
|
溫度系數
|
|
ppm/℃
|
100ppm/℃ after a 30 minute warm-up
|
|
|
|
|
|
|
|
|
保護功能
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
過電壓保護 (OVP)
|
Setting range
|
V
|
5 - 110
|
5 - 165
|
5 - 330
|
5 - 440
|
5 - 660
|
|
Setting accuracy
|
mV
|
1000
|
1500
|
3000
|
4000
|
6000
|
過電流保護 (OCP)
|
Setting range
|
A
|
1.5 - 16.5
|
1-11
|
0.5 - 5.5
|
0.38 - 4.18
|
0.26 - 2.86
|
|
Setting accuracy
|
mA
|
300
|
200
|
100
|
76
|
52
|
低電壓限制 (UVL)
|
Setting range
|
|
0 - 105
|
0 - 157.5
|
0 - 315
|
0 - 420
|
0 - 630
|
過溫度保護 (OHP)
|
Operation
|
|
關閉輸出
|
偵測線連接失效保護 (SENSE)
|
Operation
|
|
關閉輸出
|
低輸入電壓保護 (AC-FAIL)
|
Operation
|
|
關閉輸出
|
關機 (SD)
|
Operation
|
|
關閉輸出
|
功率限制 (POWER LIMIT)
|
Operation
|
|
超功率限制
|
|
Value (fixed)
|
|
Approx. 105% of rated output power
|
|
|
|
|
|
|
|
|
模擬遠端程控及監控
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
外部電壓控制輸出電壓
|
|
|
Accuracy and linearity: ±0.5% of rated output voltage.
|
外部電壓控制輸出電流
|
|
|
Accuracy and linearity: ±1% of rated output current.
|
外部電阻控制輸出電壓
|
|
|
Accuracy and linearity: ±1% of rated output voltage.
|
外部電阻控制輸出電流
|
|
|
Accuracy and linearity: ±1.5% of rated output current.
|
輸出電壓監控
|
|
|
Accuracy: ±1%
|
輸出電流監控
|
|
|
Accuracy: ±1%
|
關機控制
|
|
|
Turns the output off with a LOW (0V to 0.5V) or short-circuit.
|
輸出 開/關 控制
|
|
|
Possible logic selections:
|
Turn the output on using a LOW (0V to 0.5V) or short-circuit, turn the output off using a HIGH (4.5V to 5V) or open-circuit.
|
Turn the output on using a HIGH (4.5V to 5V) or open-circuit, turn the output off using a LOW (0V to 0.5V) or short-circuit.
|
警報控制
|
|
|
Clear alarms with a LOW (0V to 0.5V) or short-circuit.
|
CV/CC/ALM/PWR ON/OUT ON 顯示
|
|
|
Photocoupler open collector output; Maximum voltage 30V, maximum sink current 8mA.
|
觸發輸出
|
|
|
Maximum low level output = 0.8V; minimum high level output = 2V; Maximum source current = 8mA.
|
觸發輸入
|
|
|
Maximum low level input voltage = 0.8V; minimum high level input votage = 2V, Maximum sink current = 8mA.
|
|
|
|
|
|
|
|
|
前面板
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
顯示, 4 位, 電壓準確度
|
0.1% +
|
mV
|
200
|
300
|
600
|
800
|
1200
|
電流準確度
|
0.2% +
|
mA
|
45
|
30
|
15
|
11.4
|
7.8
|
指示顯示
|
|
|
GREEN LED's: CV, CC, V, A, VSR, ISR, DLY, RMT, LAN, M1, M2, M3, RUN, Output ON
|
|
|
|
RED LED's: ALM, ERR
|
按鈕
|
|
|
Lock/Local(Unlock), PROT(ALM_CLR), Function(M1), Test(M2), Set(M3), Shift, Output
|
旋鈕
|
|
|
Voltage, Current
|
USB port
|
|
|
Type A USB connector
|
|
|
|
|
|
|
|
|
程控與量測
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
(RS-232/485, USB, LAN, GPIB)
|
輸出電壓程控準確度
|
0.05% +
|
mV
|
50
|
75
|
150
|
200
|
300
|
輸出電流程控準確度
|
0.2% +
|
mA
|
15
|
10
|
5
|
3.8
|
2.6
|
輸出電壓程控解晰度
|
|
mV
|
3.4
|
5.2
|
10.2
|
13.6
|
20.4
|
輸出電流程控解晰度
|
|
mA
|
0.5
|
0.34
|
0.19
|
0.13
|
0.09
|
輸出電壓量測準確度
|
0.1% +
|
mV
|
100
|
150
|
300
|
400
|
600
|
輸出電流量測準確度
|
0.2% +
|
mA
|
30
|
20
|
10
|
7.6
|
5.2
|
輸出電壓量測解晰度
|
|
mV
|
3.4
|
5.2
|
10.2
|
13.6
|
20.4
|
輸出電流量測解晰度
|
|
mA
|
0.5
|
0.34
|
0.19
|
0.13
|
0.09
|
|
|
|
|
|
|
|
|
輸入電源特性
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
標稱輸入
|
|
|
100Vac to 240Vac, 50Hz to 60Hz, single phase
|
輸入電壓范圍
|
|
|
85Vac ~ 265Vac
|
輸入頻率范圍
|
|
|
47Hz ~ 63Hz
|
*大輸入電流
|
100Vac / 200Vac
|
A
|
21 / 11
|
涌浪電流
|
|
|
Less than 50A.
|
*大輸入功率
|
|
VA
|
2000
|
功率因數
|
100Vac / 200Vac
|
|
0.99 / 0.98
|
效率 (*13)
|
100Vac / 200Vac
|
%
|
84 / 87
|
84 / 87
|
84 / 87
|
84 / 87
|
84 / 87
|
保持時間(Hold-up time)
|
|
|
20ms or greater
|
|
|
|
|
|
|
|
|
界面相容性
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
USB
|
|
|
TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class)
|
LAN
|
|
|
MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask
|
RS-232 / RS-485
|
|
|
Complies with the EIA232D / EIA485 Specifications
|
GPIB (Factory Option)
|
|
|
SCPI - 1993, IEEE 488.2 compliant interface
|
|
|
|
|
|
|
|
|
獨立類立控制界面(Factory Option)
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
電壓控制
|
|
|
Using 0-5V or 0-10V signals for programming and measurement
|
電流控制
|
|
|
Using 4-20mA current signals for programming and measurement
|
|
|
|
|
|
|
|
|
環境條件
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
操作溫度
|
|
|
0?C to 50?C
|
儲存溫度
|
|
|
-25?C to 70?C
|
操作濕度
|
|
|
20% to 85% RH; No condensation
|
儲存濕度
|
|
|
90% RH or less; No condensation
|
高度
|
|
|
Maximum 2000m
|
|
|
|
|
|
|
|
|
一般
|
|
PSU
|
100-15
|
150-10
|
300-5
|
400-3.8
|
600-2.6
|
重量
|
主單元
|
kg
|
約 8.7kg
|
尺寸
|
(W×H×D)
|
mm^3
|
423×43.6×447.2
|
散熱
|
|
|
Forced air cooling by internal fan.
|
電磁相容性
|
|
|
Complies with the European EMC directive 2004/108/EC for Class A test and measurement products.
|
|
|
|
Complies with the European Low Voltage Directive 2006/95/EC and carries the CE-marking.
|
耐壓
|
|
|
AC to Chassis : 1500Vac / 1min
|
AC to Output terminal : 3000Vac / 1min
|
Vout≦150V
|
Output terminal to Chassis : 1000Vdc / 1min
|
150<Vout≦600
|
Output terminal to Chassis : 1500Vdc / 1min
|
絕緣阻抗
|
|
|
Chassis and output terminal; chassis and AC input; AC input and output
terminal: 100MΩ or more (DC 1000V)
|